Andrew HELIAX AVA5-50 7/8” Coaxial Cable


Compare

Andrew HELIAX AVA5-50 7/8” Coaxial Cable for Wireless Applications, is the lowest attenuation coaxial cable in the industry.

AVA5-50, HELIAX® Andrew Virtual Air™ Coaxial Cable, corrugated copper, 7/8 in, black PE jacket.

HELIAX AVA5-50 7/8” Coaxial Cable

Construction Materials  
Jacket Material   PE
Outer Conductor Material   Corrugated copper
Dielectric Material   Foam PE
Flexibility   Standard
Inner Conductor Material   Copper
Jacket Color   Black
   


Dimensions  
Nominal Size   7/8 in
Cable Weight   0.29 lb/ft   |   0.43 kg/m
Diameter Over Dielectric   24.130 mm   |   0.950 in
Diameter Over Jacket   27.991 mm   |   1.102 in
Inner Conductor OD   9.4488 mm   |   0.3720 in
Outer Conductor OD   25.400 mm   |   1.000 in
   
Category: Tags: , , ,
Electrical Specifications  
Cable Impedance   50 ohm ±1 ohm
Capacitance   22.0 pF/ft   |   73.0 pF/m
dc Resistance, Inner Conductor   0.825 ohms/kft   |   2.888 ohms/km
dc Resistance, Outer Conductor   0.400 ohms/kft   |   1.313 ohms/km
dc Test Voltage   6000 V
Inductance   0.184 µH/m   |   0.056 µH/ft
Insulation Resistance   100000 Mohms•km
Jacket Spark Test Voltage (rms)   8000 V
Operating Frequency Band   1 – 5000 MHz
Peak Power   91.0 kW
Velocity   90%
   


Environmental Specifications  
Installation Temperature   -40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature   -55 °C to +70 °C (-67 °F to +158 °F)
Storage Temperature   -70 °C to +70 °C (-94 °F to +158 °F)
   


General Specifications  
Brand   HELIAX®
Ordering Note   CommScope® non-standard product   |   Not available in the United States or Canada
   


Mechanical Specifications  
Bending Moment   27.1 N-m   |   20.0 ft lb
Flat Plate Crush Strength   75.0 lb/in
Minimum Bend Radius, Multiple Bends   254.00 mm   |   10.00 in
Minimum Bend Radius, Single Bend   127.00 mm   |   5.00 in
Number of Bends, minimum   15
Number of Bends, typical   30
Tensile Strength   159 kg   |   350 lb
   


Note  
Performance Note   Values typical, unless otherwise stated
   


Standard Conditions  
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F
Average Power, Inner Conductor Temperature   100 °C   |   212 °F

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
680–800 MHz 1.13 24.30
800–960 MHz 1.13 24.30
1700–2200 MHz 1.13 24.30

 

Attenuation

Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW)
0.5 0.08 0.024 91.00
1 0.113 0.034 74.43
1.5 0.138 0.042 60.73
2 0.16 0.049 52.56
10 0.359 0.11 23.37
20 0.51 0.156 16.46
30 0.627 0.191 13.39
50 0.814 0.248 10.32
85 1.068 0.326 7.86
88 1.088 0.332 7.72
100 1.162 0.354 7.23
108 1.209 0.368 6.95
150 1.433 0.437 5.86
174 1.548 0.472 5.43
200 1.665 0.507 5.05
204 1.682 0.513 4.99
300 2.059 0.628 4.08
400 2.398 0.731 3.50
450 2.553 0.778 3.29
500 2.7 0.823 3.11
512 2.735 0.834 3.07
600 2.977 0.907 2.82
700 3.235 0.986 2.60
800 3.478 1.06 2.42
824 3.534 1.077 2.38
894 3.694 1.126 2.27
960 3.841 1.171 2.19
1000 3.927 1.197 2.14
1218 4.377 1.334 1.92
1250 4.44 1.353 1.89
1500 4.912 1.497 1.71
1700 5.268 1.606 1.59
1800 5.439 1.658 1.54
2000 5.771 1.759 1.46
2100 5.933 1.808 1.42
2200 6.091 1.856 1.38
2300 6.247 1.904 1.34
2500 6.551 1.996 1.28
2700 6.845 2.086 1.23
3000 7.273 2.217 1.15
3400 7.819 2.383 1.07
3700 8.213 2.503 1.02
4000 8.596 2.62 0.98
5000 9.807 2.989 0.86
  • * Values typical, guaranteed within 5%

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.